Protherm Puma Condens 24 Mainboard Failed Again After Replacement

The mainboard of my Protherm Puma Condens 24 boiler developed a fault and was replaced by an authorized service center. However, since the manufacturer refused to take responsibility for the repair costs, I had to pay for the replacement myself. Due to the initial malfunction, I was unable to use my boiler for approximately one week.
After all the necessary checks were completed and I started using the appliance again, it developed another fault just 3–4 days later. This time, the display stopped receiving power entirely and the boiler became completely unusable. When the authorized service technician visited again, I was informed that the mainboard might have failed once more and that, if this was confirmed, I would have to pay for a second mainboard replacement.
I find this situation completely unacceptable. A newly replaced component should not develop the same fault within just a few days. Having to pay for another replacement so soon has caused significant inconvenience and seriously undermined my confidence in the product and the manufacturer's after-sales service. My service record number is 5505**85.
I request that this boiler, which has developed the same serious malfunction shortly after a paid repair, be evaluated as a defective product. Taking into account the amount I have already paid for the mainboard replacement, I demand that the faulty appliance be replaced with a brand-new, defect-free unit at no additional cost. I also expect the manufacturer to take responsibility for this recurring problem rather than requiring me to pay repeatedly for the same malfunction.